<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Oxygen Transmission Rate Tester &#124; OTR Tester &#124; Oxygen Permeability Tester &#187; oxygen permeation instrument</title>
	<atom:link href="http://www.oxygen-transmission-rate.com/tag/oxygen-permeation-instrument/feed" rel="self" type="application/rss+xml" />
	<link>http://www.oxygen-transmission-rate.com</link>
	<description>Oxygen Permeability Tester is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches.</description>
	<lastBuildDate>Fri, 24 Apr 2026 06:30:55 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.3</generator>
		<item>
		<title>New Oxygen Transmission Rate Test System Lanuched &#8211; C203H</title>
		<link>http://www.oxygen-transmission-rate.com/new-oxygen-transmission-rate-test-system-lanuched-c203h.html</link>
		<comments>http://www.oxygen-transmission-rate.com/new-oxygen-transmission-rate-test-system-lanuched-c203h.html#comments</comments>
		<pubDate>Sun, 04 Feb 2024 08:11:49 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Products]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>
		<category><![CDATA[Oxygen Transmission Rate Test System]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=497</guid>
		<description><![CDATA[New Oxygen Transmission Rate Test System equipped with Labthink ppb level Coulometric Oxygen Sensor is Lanuched &#8211; C203H Oxygen Transmission Rate Test System! C203H Oxygen Transmission Rate Test System is based on Coulometric oxygen analysis sensor and equal pressure test method, and is conforming to ASTM D 3985 and other standards. It provides high-precision and high-efficiency [...]]]></description>
			<content:encoded><![CDATA[<p><strong>New Oxygen Transmission Rate Test System equipped with Labthink ppb level Coulometric Oxygen Sensor is Lanuched &#8211; C203H Oxygen Transmission Rate Test System!</strong></p>
<p style="text-align: center;"><strong><a href="https://en.labthink.com/en-us/product/c203h-oxygen-transmission-rate-test-system.html"><img class="aligncenter" title="C203H Oxygen Transmission Rate Test System" src="https://en.labthink.com/productpics/big/c203h.jpg" alt="C203H Oxygen Transmission Rate Test System" width="735" height="551" /></a></strong></p>
<p style="text-align: left;"><strong><a title="C203H Oxygen transmission rate test system" href="https://en.labthink.com/en-us/product/c203h-oxygen-transmission-rate-test-system.html" target="_blank">C203H Oxygen Transmission Rate Test System</a></strong> is based on Coulometric oxygen analysis sensor and equal pressure test method, and is conforming to ASTM D 3985 and other standards. It provides high-precision and high-efficiency oxygen permeability tests for high and medium gas barrier materials. It is suitable for testing the oxygen permeability of thin films, sheets and related materials in the fields of food, medicine, medical devices, daily chemical, photovoltaic, electronic and other fields.</p>
<p style="text-align: left;"><strong>Advantages</strong></p>
<ul>
<li>Labthink ppb level Coulometric Oxygen Sensor</li>
<li>Accurate Data</li>
<li>Effective Three-Cell</li>
<li>Intelligent Operation</li>
<li>Safe and Reliable</li>
<li>Powerful Functions</li>
</ul>
<p><strong>Standards</strong></p>
<p>This C203H Oxygen Transmission Rate Test System conforms to ASTM D3985, ASTM F1307, ASTM F1927(option)</p>
<p><strong>Technical Index</strong></p>
<table border="0" cellspacing="0" cellpadding="0" width="100%">
<tbody>
<tr>
<th colspan="2">Parameters/Model</th>
<th>C203H</th>
</tr>
<tr>
<td rowspan="4"><strong>Test Scope</strong></td>
<td>cc/(m2·day) (standard area 50cm2)</td>
<td>0.01～200<br />
0.005～200 (optional)</td>
</tr>
<tr>
<td>cc/(m2·day) (standard area 50cm2)</td>
<td>0.01～400000（Customize）</td>
</tr>
<tr>
<td>cc/(m2·day) (MASK area 5cm2)</td>
<td>0.1~2000 (optional)</td>
</tr>
<tr>
<td>cc/(m2·day) (MASK area 1cm2)</td>
<td>0.5~10000 (optional)</td>
</tr>
<tr>
<td><strong>Resolving Power</strong></td>
<td>cc/(m2·day)</td>
<td>0.0001</td>
</tr>
<tr>
<td><strong>Repeatability</strong></td>
<td>cc/(m2·day)</td>
<td>0.01 or1%, whichever is greater</td>
</tr>
<tr>
<td><strong>Temperature Range </strong></td>
<td>℃</td>
<td>15～50<br />
5~60 (customized)</td>
</tr>
<tr>
<td><strong>Temperature Fluctuation</strong></td>
<td>℃</td>
<td>±0.05</td>
</tr>
<tr>
<td><strong>Humidity Range</strong></td>
<td>%Rh (within standard temperature range)</td>
<td>O2: 0%，5～90%±1%<br />
Carrier Gas: 0%, 5～90%±2%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/new-oxygen-transmission-rate-test-system-lanuched-c203h.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Oxygen Transmission Rate Instrument</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html#comments</comments>
		<pubDate>Thu, 13 Oct 2011 07:02:41 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>
		<category><![CDATA[oxygen transmission rate]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=122</guid>
		<description><![CDATA[PERME OX2/231 Oxygen Transmission Rate Instrument is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches. Oxygen Transmission Rate Instrument conforms to ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 and GB/T 19789.]]></description>
			<content:encoded><![CDATA[<p>PERME OX2/231 <strong>Oxygen Transmission Rate Instrument</strong> is applicable for the <em>oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches</em>.</p>
<p><strong>Oxygen Transmission Rate Instrument</strong> conforms to <span style="color: #ff6600;">ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 and GB/T 19789</span>.</p>
<p><strong>Oxygen Transmission Rate Instrument Principle<br />
</strong>Oxygen flows in one side of the film, and nitrogen flows on the other side. The oxygen molecules permeate through the film and into the nitrogen side, and are then carried to the sensor by the flowing nitrogen. By analyzing the oxygen concentration measured by the sensor, oxygen transmission rate and other parameters can be calculated. As to packages, nitrogen flows inside the packages, and oxygen flows outside the packages.</p>
<div><strong>Technical Indexes<br />
</strong>Oxygen Transmission Rate Instrument For Film Testing Technical Indexes</div>
<div>Test Range: 0.01~1000 cm<sup>3</sup>/m<sup>2</sup>·day</div>
<div>0.1~10,000 cm<sup>3</sup>/m<sup>2</sup>·day (optional)</div>
<div>Resolution: 0.01 cm<sup>3</sup>/m<sup>2</sup>·day</div>
<div>No. of Specimens: 1 to 3 specimens.</div>
<div>Temperature Control Range: 15℃~55℃ (optional purchase)</div>
<div>Temperature Control Precision: ±0.1℃</div>
<div>Humidity Control Range: 0%RH; 15%RH~90%RH ; 100%RH (optional purchase)</div>
<div>Humidity Control Precision: ±1%RH</div>
<div>Specimen Size: 108×108 mm</div>
<div>Test Area: 50cm<sup>2</sup></div>
<div>Test Gas: oxygen and air, etc. (users provide gas sources themselves)</div>
<div>Inlet Size: Φ4mm polyurethane pipe</div>
<div>Carrier Gas: high pure nitrogen with the concentration no less than 99.999% (users provide gas sources themselves)</div>
<div>Inlet Size: 1/8 inch metal pipe</div>
<div>Power: AC (85~264) V (47~63) Hz</div>
<div>Dimensions: 670mm (L)×410mm(B)×310mm(H)</div>
<div>Net Weight: 48Kg</div>
<div>For more information, please feel free to contact Jerry via:<br />
Tel:86-531-85068566</div>
<div>Mail:marketing@labthink.cn</div>
<div>Website:http://www.labthink.cn/en</div>
<div>Related Products: <a href="http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html" target="_blank">Oxygen Permeation Test System</a> </div>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Oxygen Permeation Test System</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html#comments</comments>
		<pubDate>Wed, 23 Feb 2011 07:43:33 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen permeation]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>
		<category><![CDATA[Oxygen Permeation Test System]]></category>
		<category><![CDATA[oxygen permeation tester]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=76</guid>
		<description><![CDATA[Oxygen Permeation Test System is applicable in the oxygen permeation testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials. Oxygen Permeation Test System conforms to ASTM F1307, ASTM D3985, ASTM [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Oxygen Permeation Test System </strong>is applicable in the <em>oxygen permeation testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials</em>.</p>
<p><strong> </strong></p>
<p><strong>Oxygen Permeation Test System </strong>conforms to <span style="text-decoration: underline;">ASTM F1307, ASTM D3985, ASTM F1927, ISO 15105-2, JIS K7126 etc.</span></p>
<p><strong> </strong></p>
<p><strong>Features:</strong></p>
<p><strong>1.</strong> <strong>Computer control </strong>with both <strong>films and containers</strong> test types.</p>
<p><strong>2. Three testing chambers integrated in one block. </strong></p>
<p><strong>3. </strong>One master base can connect 9 satellite modules;<strong> thirty specimens testable simultaneously;</strong></p>
<p><strong>4. </strong>Mixed testing control for oxygen and water vapor transmission rate</p>
<p><strong>5. Test process will not be influenced by power off</strong></p>
<p><strong>Technical Data:</strong></p>
<p>1.For Film;</p>
<p>Test Range:0.01～6500cm3/m2•day(Routine)</p>
<p>0.07～65000cm3/m2•day (Optional)</p>
<p>Resolution: 0.001 ml/m2•day</p>
<p>Temp. Control Range: 15℃～55℃(Routine)</p>
<p>Humidity Control Range: 0%RH; 35%RH～90%RH; 100%RH</p>
<p>2.For Container;</p>
<p>Test Range:0.0001～60 cm3/pkg•day</p>
<p>Resolution: 0.00001cm3/ pkg•day</p>
<p>Temp. Control Range: 15℃～55℃ (Routine)</p>
<p>Humidity Control Range: 0%RH; 35%RH～90%RH; 100%RH</p>
<p>For more information, please feel free to contact us via trade2@labthink.cn or (tel)0086-531-85811021.</p>
<p><strong> </strong></p>
<p><strong>Related products:</strong></p>
<p>PERME<sup>TM</sup> OX2/231 <a href="http://www.labthinkinternational.com.cn/products/test-property/gas-permeability-test.html" target="_blank">Oxygen Transmission Rate (OTR) Tester</a></p>
<p>PERME<sup>TM</sup> TOY-C2 Oxygen Permeability Tester</p>
<p>PERME<sup>TM</sup> TOY-C1 Oxygen Permeation Tester</p>
<p>PERME<sup>TM</sup> DM2/330 Gas Permeability Testing Instrument</p>
<p>PERME<sup>TM</sup> W3/330 Water Vapor Permeation Test System</p>
<p>More about <a href="http://www.labthinkinternational.com.cn/">Labthink:</a></p>
<p>Labthink provides excellent testing equipments and services for Labs, quality and safety control of polymer materials, such as flexible packaging, pharmaceuticals, foodstuff, cosmetics packaging, printing, adhesive, automotive, petroleum chemistry, environment, biology, new energy, construction, astronautics and electronics.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html/feed</wfw:commentRss>
		<slash:comments>37</slash:comments>
		</item>
		<item>
		<title>Oxygen Permeation Measurement for Contact Lens</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-permeation-measurement-for-contact-lens.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-permeation-measurement-for-contact-lens.html#comments</comments>
		<pubDate>Tue, 28 Dec 2010 02:04:39 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News & Notice]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=4</guid>
		<description><![CDATA[Recently, the first professional contact lens oxygen permeation instrument has been launched by Labthink. Oxygen permeation tester complies to the related ISO standards completely, and the test results are very ideal. ]]></description>
			<content:encoded><![CDATA[<p>Recently, the first professional contact lens <strong>oxygen permeation</strong> instrument has been launched by Labthink. <strong>Oxygen permeation</strong> Instrument complies to the related ISO standards completely, and the test results are very ideal.</p>
<p>It is well known that the level of oxygen permeation of contact lens will affect the level of the comfort that they provide for the wearers, and then it would have an impact on contact lens&#8217; sale, therefore, the contact lens oxygen permeation test of attracts the most attention from the contact lens manufacturers. <em>Meanwhile ISO also constituted the relevant testing standards for the oxygen permeation test of contact lens: ISO 9913-1 Optics and optical instruments — Contact lens.</em></p>
<p>The test principle and test equipment stipulated by ISO 9913-2 are close to the coulometric method used by oxygen permeation test of flex packaging materials. The mounted sample divides the cell into test gas cell and carrier gas cell. The test gas passes through the sample into the carrier gas cell and is carried by the carrier gas to the sensor. The sensor detects the amount of the test gas passed.</p>
<p>From the above principle, the oxygen permeation test of contact lens and flexible packaging materials are approximately divided into the following steps: zero point test for system, fill oxygen into test chamber, output value of sensor goes steady (judge penetration equilibrium), get test results.</p>
<p>Before formal tests, the oxygen permeation test equipment needs to be calibrated with reference film. The ISO 9913-2 standard clearly pointed out the sample used for calibration: SRM1470, this film is exactly same with the reference film used in ASTM D 3985 standards. So it also proves that the comparability between oxygen permeation test of contact lens and flexible packaging material.</p>
<p>However, there are also some differences between the test of contact lens and flex packaging materials, that are mainly divided into two points:</p>
<p>Firstly, the fixture of sample is different; mainly on the shape and area of samples.</p>
<p>Secondly, test environment is different, the standard temperature of film oxygen permeation test is 23℃, whereas, in order to simulate the actual human use, the test temperature of contact lens ought to be 35℃. Meanwhile, the temperature change will affect test result observably, therefore, the stability of temperature is very important during test.</p>
<p><em>Labthink designed and manufactured clamps accessories, temperature controller settings specially for the contact lens test based on the existing, Oxygen Permeation Tester, the professional oxygen permeation tester of flexible packaging materials. Not only is the special shape of the samples considered, but also the special test environment is simulated.</em>Further details please feel free to contact Shirley via <a href="mailto:trade2@labthink.cn">trade2@labthink.cn</a> or (tel)0086-531-85811021 at Labthink.</p>
<p><em><em>Labthink is a professional manufacturer of testing equipments for packaging industry. Labthink focus on research and development of the packaging materials&#8217; permeation properties test technique. </em></em></p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-permeation-measurement-for-contact-lens.html/feed</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>
