<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Oxygen Transmission Rate Tester &#124; OTR Tester &#124; Oxygen Permeability Tester &#187; Oxygen Transmission Rate Tester</title>
	<atom:link href="http://www.oxygen-transmission-rate.com/tag/oxygen-transmission-rate-tester/feed" rel="self" type="application/rss+xml" />
	<link>http://www.oxygen-transmission-rate.com</link>
	<description>Oxygen Permeability Tester is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches.</description>
	<lastBuildDate>Fri, 24 Apr 2026 06:30:55 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.3</generator>
		<item>
		<title>Oxygen Transmission Rate of PET Bottle</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-pet-bottle.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-pet-bottle.html#comments</comments>
		<pubDate>Thu, 16 Oct 2014 07:31:09 +0000</pubDate>
		<dc:creator>trade</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen transmission rate]]></category>
		<category><![CDATA[oxygen transmission rate of PET Bottle]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=293</guid>
		<description><![CDATA[PET Bottle is more and more used in food and pharmaceutical package industries. So Oxygen Transmission Rate of PET Bottle measurement is also more important to make sure the content quality and the product shelf life. Labthink OX2/230 Oxygen Transmission Rate Tester is not only used for oxygen transmission rate testing for plastic film and [...]]]></description>
			<content:encoded><![CDATA[<p>PET Bottle is more and more used in food and pharmaceutical package industries. So Oxygen Transmission Rate of PET Bottle measurement is also more important to make sure the content quality and the product shelf life.</p>
<p>Labthink OX2/230 <a title="oxygen transmission rate tester" href="http://www.labthinkinternational.com.cn/product/ox2-230-oxygen-transmission-rate-test-system.html" target="_blank">Oxygen Transmission Rate Tester</a> is not only used for <a title="oxygen transmission rate" href="http://www.labthinkinternational.com.cn/product/ox2-230-oxygen-transmission-rate-test-system.html" target="_blank">oxygen transmission rate</a> testing for plastic film and aluminum foil, but also can be used for PET Bottle with special fixture.</p>
<p>Although caps and closures equate to only 0.5% to 6% of the total package, it is worthwhile to check their contribution to any oxygen ingress. This paper provides some ideas and guidelines regarding the testing of caps and closures with respect to their oxygen transmission rate contribution of the package.</p>
<div>There are several challenging tasks that bottle caps need to perform:</div>
<div>
<ul>
<li><span style="font-size: 13px;line-height: 19px">It should be easy to open</span></li>
<li><span style="font-size: 13px;line-height: 19px">It must be tamper proof</span></li>
<li><span style="font-size: 13px;line-height: 19px">It must be tight under all conditions for transportation and storage</span></li>
<li><span style="font-size: 13px;line-height: 19px">Its integration into the complete package</span></li>
<li><span style="font-size: 13px;line-height: 19px">There are several challenging tasks that bottle caps need to perform:</span></li>
<li><span style="font-size: 13px;line-height: 19px">It should be easy to openIt must be tamper proofIt must be tight under all conditions for transportation and storageIts integration into the complete package</span></li>
</ul>
</div>
<p>Don&#8217;t worry, Labthink OX2/230 help you resolve all these problems.</p>
<p><a href="http://www.labthinkinternational.com.cn/contact/index.html" target="_blank">Request more information </a>to see how Labthink can help your organization with Oxygen Transmission Rate of PET Bottle.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-pet-bottle.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Oxygen Transmission Rate of Aluminum Foil</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-aluminum-foil.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-aluminum-foil.html#comments</comments>
		<pubDate>Thu, 16 Oct 2014 05:48:41 +0000</pubDate>
		<dc:creator>trade</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen transmission rate]]></category>
		<category><![CDATA[oxygen transmission rate of aliminum foil]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=290</guid>
		<description><![CDATA[Aluminum foils are commonly used in food packaging industry, so measuring oxygen transmission rate of aluminum foil is becoming more important. Labthink OX2/230 Oxygen Transmission Rate Tester is professionally designed to measure oxygen transmission rate of aluminum foil and equipped with high precision oxygen sensor with a wide test range 0.01~65000cm3/m2·d. This Oxygen Transmission Rate [...]]]></description>
			<content:encoded><![CDATA[<p>Aluminum foils are commonly used in food packaging industry, so measuring <a title="Oxygen transmission rate" href="http://www.labthinkinternational.com.cn/product/ox2-230-oxygen-transmission-rate-test-system.html" target="_blank">oxygen transmission rate</a> of aluminum foil is becoming more important.</p>
<p>Labthink OX2/230 <a title="oxygen transmission rate tester" href="http://www.labthinkinternational.com.cn/product/ox2-230-oxygen-transmission-rate-test-system.html" target="_blank">Oxygen Transmission Rate Tester</a> is professionally designed to measure oxygen transmission rate of aluminum foil and equipped with high precision oxygen sensor with a wide test range 0.01~65000cm3/m2·d.</p>
<p>This Oxygen Transmission Rate Tester conforms to <a title="ASTM D3985" href="http://www.labthinkinternational.com.cn/products/standard/astm-d3985.html" target="_blank">ASTM D3985</a>: At a selected temperature and humidity, a barrier film is sealed between a chamber containing oxygen and a chamber void of oxygen. A coulometric sensor measures the oxygen that is transmitted through the material.</p>
<p>Specimen Size: 108 mm x 108 mm with thickness no more than 3mm, of course, for some special specimen, customization is also available.</p>
<p>Request more information to see how Labthink can help your organization with Oxygen Transmission Rate of Aluminum Foil.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-aluminum-foil.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Arrival &#8211; Differential Pressure Method Oxygen Permeability Tester</title>
		<link>http://www.oxygen-transmission-rate.com/new-arrival-differential-pressure-method-oxygen-permeability-tester.html</link>
		<comments>http://www.oxygen-transmission-rate.com/new-arrival-differential-pressure-method-oxygen-permeability-tester.html#comments</comments>
		<pubDate>Tue, 14 May 2013 03:33:01 +0000</pubDate>
		<dc:creator>trade</dc:creator>
				<category><![CDATA[News & Notice]]></category>
		<category><![CDATA[differential pressure method]]></category>
		<category><![CDATA[gas permeability tester]]></category>
		<category><![CDATA[gas transmission rate tester]]></category>
		<category><![CDATA[Oxygen permeability tester]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=234</guid>
		<description><![CDATA[A new product arrived at Labthink &#8211; G2/132 Gas (Oxygen) Permeability Tester. It is based new designed based on differential pressure method and adopts Labthink’s exclusive patent design of three diffusion cells integrated in one instrument for individual or multiple tests, which improves test efficiency by 3 times. This Gas (Oxygen) Permeability Tester keeps Labthink [...]]]></description>
			<content:encoded><![CDATA[<p>A new product arrived at Labthink &#8211; G2/132 <a href="http://www.labthinkinternational.com.cn/products/test-property/gas-permeability-test.html" target="_blank">Gas (Oxygen) Permeability Tester</a>. It is based new designed based on differential pressure method and adopts Labthink’s exclusive patent design of three diffusion cells integrated in one instrument for individual or multiple tests, which improves test efficiency by 3 times.</p>
<p><a href="http://www.oxygen-transmission-rate.com/wp-content/uploads/2013/05/G2-132.jpg"><img class="alignnone size-medium wp-image-237" src="http://www.oxygen-transmission-rate.com/wp-content/uploads/2013/05/G2-132-300x212.jpg" alt="" width="300" height="212" /></a></p>
<p>This Gas (Oxygen) Permeability Tester keeps Labthink the other <a href="http://www.labthinkinternational.com.cn/product/g2-132-gas-permeability-tester.html" target="_blank">gas permeability tester</a> features, like:</p>
<ul>
<li>Wide test range for different materials with high, medium and low barrier properties</li>
<li>Wide range and high precision of automatic temperature and humidity control to support various combinations of non-standard test conditions</li>
<li>Convenient fast-access calibration port for temperature and humidity</li>
<li>Reference film calibration ensures accurate and general test data</li>
<li>Equipped with standard and convenient RS232 port</li>
</ul>
<p>Besides, Labthink G2/132 utilizes Labthink&#8217;s latest generation of intelligent operating software and the testing process is completely automatic. It supports Lystem™ Lab Data Sharing System, which ensures uniformly management of test results and test reports.</p>
<p>This G2/132 Gas Permeability Tester conforms to ISO 2556, ISO 15105-1, ASTM D1434</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/new-arrival-differential-pressure-method-oxygen-permeability-tester.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Oxygen Transmission Rate Instrument</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html#comments</comments>
		<pubDate>Thu, 13 Oct 2011 07:02:41 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>
		<category><![CDATA[oxygen transmission rate]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=122</guid>
		<description><![CDATA[PERME OX2/231 Oxygen Transmission Rate Instrument is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches. Oxygen Transmission Rate Instrument conforms to ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 and GB/T 19789.]]></description>
			<content:encoded><![CDATA[<p>PERME OX2/231 <strong>Oxygen Transmission Rate Instrument</strong> is applicable for the <em>oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches</em>.</p>
<p><strong>Oxygen Transmission Rate Instrument</strong> conforms to <span style="color: #ff6600;">ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 and GB/T 19789</span>.</p>
<p><strong>Oxygen Transmission Rate Instrument Principle<br />
</strong>Oxygen flows in one side of the film, and nitrogen flows on the other side. The oxygen molecules permeate through the film and into the nitrogen side, and are then carried to the sensor by the flowing nitrogen. By analyzing the oxygen concentration measured by the sensor, oxygen transmission rate and other parameters can be calculated. As to packages, nitrogen flows inside the packages, and oxygen flows outside the packages.</p>
<div><strong>Technical Indexes<br />
</strong>Oxygen Transmission Rate Instrument For Film Testing Technical Indexes</div>
<div>Test Range: 0.01~1000 cm<sup>3</sup>/m<sup>2</sup>·day</div>
<div>0.1~10,000 cm<sup>3</sup>/m<sup>2</sup>·day (optional)</div>
<div>Resolution: 0.01 cm<sup>3</sup>/m<sup>2</sup>·day</div>
<div>No. of Specimens: 1 to 3 specimens.</div>
<div>Temperature Control Range: 15℃~55℃ (optional purchase)</div>
<div>Temperature Control Precision: ±0.1℃</div>
<div>Humidity Control Range: 0%RH; 15%RH~90%RH ; 100%RH (optional purchase)</div>
<div>Humidity Control Precision: ±1%RH</div>
<div>Specimen Size: 108×108 mm</div>
<div>Test Area: 50cm<sup>2</sup></div>
<div>Test Gas: oxygen and air, etc. (users provide gas sources themselves)</div>
<div>Inlet Size: Φ4mm polyurethane pipe</div>
<div>Carrier Gas: high pure nitrogen with the concentration no less than 99.999% (users provide gas sources themselves)</div>
<div>Inlet Size: 1/8 inch metal pipe</div>
<div>Power: AC (85~264) V (47~63) Hz</div>
<div>Dimensions: 670mm (L)×410mm(B)×310mm(H)</div>
<div>Net Weight: 48Kg</div>
<div>For more information, please feel free to contact Jerry via:<br />
Tel:86-531-85068566</div>
<div>Mail:marketing@labthink.cn</div>
<div>Website:http://www.labthink.cn/en</div>
<div>Related Products: <a href="http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html" target="_blank">Oxygen Permeation Test System</a> </div>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-transmission-rate-instrument.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Oxygen Permeation Test System</title>
		<link>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html</link>
		<comments>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html#comments</comments>
		<pubDate>Wed, 23 Feb 2011 07:43:33 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[oxygen permeation]]></category>
		<category><![CDATA[oxygen permeation instrument]]></category>
		<category><![CDATA[Oxygen Permeation Test System]]></category>
		<category><![CDATA[oxygen permeation tester]]></category>
		<category><![CDATA[Oxygen Transmission Rate Tester]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=76</guid>
		<description><![CDATA[Oxygen Permeation Test System is applicable in the oxygen permeation testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials. Oxygen Permeation Test System conforms to ASTM F1307, ASTM D3985, ASTM [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Oxygen Permeation Test System </strong>is applicable in the <em>oxygen permeation testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials</em>.</p>
<p><strong> </strong></p>
<p><strong>Oxygen Permeation Test System </strong>conforms to <span style="text-decoration: underline;">ASTM F1307, ASTM D3985, ASTM F1927, ISO 15105-2, JIS K7126 etc.</span></p>
<p><strong> </strong></p>
<p><strong>Features:</strong></p>
<p><strong>1.</strong> <strong>Computer control </strong>with both <strong>films and containers</strong> test types.</p>
<p><strong>2. Three testing chambers integrated in one block. </strong></p>
<p><strong>3. </strong>One master base can connect 9 satellite modules;<strong> thirty specimens testable simultaneously;</strong></p>
<p><strong>4. </strong>Mixed testing control for oxygen and water vapor transmission rate</p>
<p><strong>5. Test process will not be influenced by power off</strong></p>
<p><strong>Technical Data:</strong></p>
<p>1.For Film;</p>
<p>Test Range:0.01～6500cm3/m2•day(Routine)</p>
<p>0.07～65000cm3/m2•day (Optional)</p>
<p>Resolution: 0.001 ml/m2•day</p>
<p>Temp. Control Range: 15℃～55℃(Routine)</p>
<p>Humidity Control Range: 0%RH; 35%RH～90%RH; 100%RH</p>
<p>2.For Container;</p>
<p>Test Range:0.0001～60 cm3/pkg•day</p>
<p>Resolution: 0.00001cm3/ pkg•day</p>
<p>Temp. Control Range: 15℃～55℃ (Routine)</p>
<p>Humidity Control Range: 0%RH; 35%RH～90%RH; 100%RH</p>
<p>For more information, please feel free to contact us via trade2@labthink.cn or (tel)0086-531-85811021.</p>
<p><strong> </strong></p>
<p><strong>Related products:</strong></p>
<p>PERME<sup>TM</sup> OX2/231 <a href="http://www.labthinkinternational.com.cn/products/test-property/gas-permeability-test.html" target="_blank">Oxygen Transmission Rate (OTR) Tester</a></p>
<p>PERME<sup>TM</sup> TOY-C2 Oxygen Permeability Tester</p>
<p>PERME<sup>TM</sup> TOY-C1 Oxygen Permeation Tester</p>
<p>PERME<sup>TM</sup> DM2/330 Gas Permeability Testing Instrument</p>
<p>PERME<sup>TM</sup> W3/330 Water Vapor Permeation Test System</p>
<p>More about <a href="http://www.labthinkinternational.com.cn/">Labthink:</a></p>
<p>Labthink provides excellent testing equipments and services for Labs, quality and safety control of polymer materials, such as flexible packaging, pharmaceuticals, foodstuff, cosmetics packaging, printing, adhesive, automotive, petroleum chemistry, environment, biology, new energy, construction, astronautics and electronics.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/oxygen-permeation-test-system.html/feed</wfw:commentRss>
		<slash:comments>37</slash:comments>
		</item>
	</channel>
</rss>
