<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Oxygen Transmission Rate Tester &#124; OTR Tester &#124; Oxygen Permeability Tester &#187; packaging barrier</title>
	<atom:link href="http://www.oxygen-transmission-rate.com/tag/packaging-barrier/feed" rel="self" type="application/rss+xml" />
	<link>http://www.oxygen-transmission-rate.com</link>
	<description>Oxygen Permeability Tester is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches.</description>
	<lastBuildDate>Fri, 24 Apr 2026 06:30:55 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.3</generator>
		<item>
		<title>Barrier Property of Package</title>
		<link>http://www.oxygen-transmission-rate.com/barrier-property-of-package.html</link>
		<comments>http://www.oxygen-transmission-rate.com/barrier-property-of-package.html#comments</comments>
		<pubDate>Thu, 17 Mar 2011 09:08:05 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[barrier property]]></category>
		<category><![CDATA[barrier test]]></category>
		<category><![CDATA[packaging barrier]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=75</guid>
		<description><![CDATA[Abstract: This article details on the test method of bottle body that has complete bottle-cap sealing. 1.  Current Situation of Package Barrier Property Testing Package is one of the main forms in liquid packing. Barrier property of the package has a direct influence on quality guarantee period of products. Generally speaking, the better the barrier [...]]]></description>
			<content:encoded><![CDATA[<p>Abstract: This article details on the test method of bottle body that has complete bottle-cap sealing.</p>
<p>1.  Current Situation of Package <a href="http://www.labthink.cn/en/product-info-1010100.html">Barrier Property Testing</a></p>
<p>Package  is one of the main forms in liquid packing. Barrier property of the  package has a direct influence on quality guarantee period of products.  Generally speaking, the better the barrier property of package is, the  longer the quality guarantee period will be. To products such as alcohol  or perfume that possess special odor, the package should have better  barrier property to elements that will easily cause product  deterioration, such as oxygen and water vapor. Moreover, the package  should ensure that special perfume of these products would not dissipate  during storage.</p>
<p>Because  package is directly used in liquid packing, its shape and specification  is very difficult to unify. That is why package testing is difficult to  carry out and develops more slowly than film barrier property testing.  In barrier property testing of the package, test of common gases  occupies a large demand. In the past, gas permeance is estimated by  testing package sheet material. However, package wall is not uniform in  thickness and material nature will be changed in the process of  production, which will cause certain disparity existing between  estimated and actual gas permeance of the package. Among various test  technologies, package oxygen permeability enjoys the rapidest  development. The introduction of ASTM F 1307 standard for package oxygen  permeability test method not only accelerated the research and  popularization of package oxygen permeability instruments, test results  also becomes more scientific and accurate, which changed the former  condition of chaotic test methods and lower credibility of test data.</p>
<p>Except  for metal cans and packing box of pulp-molded aluminum, one complete  package mainly consists of bottle body and bottle cap. At present, the  test of package oxygen permeability mainly aims at bottle body or bottle  cap. However, to one package, so long as its bottle body and bottle cap  are not one integral part, leakage of the connecting place will greatly  decrease overall barrier property of package, even if both bottle body  and bottle cap can achieve high barrier property. Connecting place of  the bottle is like heat-sealing place of flexible package, where leakage  point will cause a failure of barrier property protection to inner  content. Therefore, the connecting place of package (especially the  detachable package except for metal cans and packing box of pulp-molded  aluminum) is one weak point of package barrier property.</p>
<p>2.  Integral Test of <a href="http://www.labthink.cn/en/product-info-1010100.html">Package Barrier Property</a></p>
<p>At  present, methods for overall barrier property test of sealed bottle are  very rare. Based on the oxygen permeability test of common bottle body,  Labthink made some improvements and has find a method for overall  barrier property test of sealed bottle. Here we will take one actual  test of Labthink lab as an example for explanation.</p>
<ul>
<li> Instrument: Labthink TOY-C1 film/package oxygen permeability instrument</li>
<li>Specimen: glass bottle (metal cap)</li>
<li>Test item: oxygen permeance of bottle cap and sealing place</li>
<li>Test environment: standard lab environment</li>
<li>In the following part, the test method is introduced step by step.</li>
</ul>
<p>2.1 Specimen Preparation</p>
<p>First,  prepare effective test specimen. The method of preparation is almost  the same with that of bottle body oxygen permeability test, which  include preparation of test instrument, specimen pretreatment and tools  needed in the process of test. However, specimen placement is not the  same.</p>
<p>When  test barrier property of bottle body, the package should be laid upside  down and fixed onto special bottle pedestal manufactured by Labthink.  Then seal bottle neck by filling special glue into bottle pedestal in  order to avoid the transmission of oxygen from connecting place of  bottle pedestal and bottleneck into bottle body. Generally, the finished  specimen is shown as figure 1.</p>
<table cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td width="24" height="10"></td>
<td width="336"></td>
<td width="72"></td>
<td width="216"></td>
</tr>
<tr>
<td height="316"></td>
<td align="left" valign="top"></td>
<td><img src="http://upload.labthink.cn/Pictures/2011/Origin/57a01.jpg" alt="57a01.jpg" width="259" height="255" /></td>
<td rowspan="2" align="left" valign="top"></td>
</tr>
<tr>
<td height="3"></td>
</tr>
</tbody>
</table>
<p><img src="http://upload.labthink.cn/Pictures/2011/Origin/57a02.jpg" alt="57a02.jpg" /> Figure 1                                                                   Figure 2</p>
<p>In  overall barrier property testing of bottle cap and bottle body, place  the bottle upward on the center of tailor-made bottle pedestal (please  refer to the article ‘TOY-C1 Package Oxygen Permeability Test’). Then  fill the sealing glue evenly into between bottle body and bottle  pedestal. Make sure that the space between bottom recess and input and  output pipes is also filled with sealing glue. The finished specimen is  shown as figure 2.</p>
<p>It  should be noted that unit mounting must be carried out after the  complete solidification of sealing glue. Otherwise movement of specimen  may cause failure of sealing glue, i.e., failure of package sealing.</p>
<p>2.2 Specimen Placement and Test</p>
<p>Similar  to the method of bottle body test, install the prepared specimen and  other accessories to lower chamber of instrument (please refer to the  article ‘TOY-C1 Package Oxygen Permeability Test’). Then the test can be  started. The test method is completely the same with that of bottle  body oxygen permeability.</p>
<p><img src="http://upload.labthink.cn/Pictures/2011/Origin/57a03.jpg" alt="57a03.jpg" width="292" height="347" /></p>
<p>Figure 3. Test condition</p>
<p>3. Conclusion</p>
<p>Oxygen  permeability test method for sealed bottle introduced in this article  is based on oxygen permeability test of common bottle body, among which  preparation of specimen and specimen unit is the difficult points. This  method can also be used for overall oxygen permeability test of metal  cans and pulp-molded aluminum flexible package. Wide application of this  method not only can offer great help to a comprehensive understanding  of package barrier property, it can also provide data support to  structure designing and cost saving of package.</p>