<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Oxygen Transmission Rate Tester &#124; OTR Tester &#124; Oxygen Permeability Tester &#187; vci packaging</title>
	<atom:link href="http://www.oxygen-transmission-rate.com/tag/vci-packaging/feed" rel="self" type="application/rss+xml" />
	<link>http://www.oxygen-transmission-rate.com</link>
	<description>Oxygen Permeability Tester is applicable for the oxygen transmission rate determination of plastic films, laminated films, sheets as well as packages, like plastic bottles and pouches.</description>
	<lastBuildDate>Fri, 24 Apr 2026 06:30:55 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.3</generator>
		<item>
		<title>VCI (Volatile Corrosion Inhibition) Package Quality Control Testing Solution</title>
		<link>http://www.oxygen-transmission-rate.com/vci-volatile-corrosion-inhibition-package-quality-control-testing-solution.html</link>
		<comments>http://www.oxygen-transmission-rate.com/vci-volatile-corrosion-inhibition-package-quality-control-testing-solution.html#comments</comments>
		<pubDate>Thu, 14 Jul 2011 08:21:03 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Applications Ariticles]]></category>
		<category><![CDATA[barrier test]]></category>
		<category><![CDATA[vci packaging]]></category>

		<guid isPermaLink="false">http://www.oxygen-transmission-rate.com/?p=111</guid>
		<description><![CDATA[Volatile Corrosion Inhibition (VCI) has found its wild application, and has completely promoted metal antirust from grease. Now, in the field for high quality rust-proof applications, including military, precision machinery, ironware, measuring and blade wares, electric and electronic applications, machinery processing, storage and voyage as well as high requirements for export goods, VCI packages have [...]]]></description>
			<content:encoded><![CDATA[<p>Volatile Corrosion Inhibition (VCI) has found its wild application,  and has completely promoted metal antirust from grease. Now, in the  field for high quality rust-proof applications, including military,  precision machinery, ironware, measuring and blade wares, electric and  electronic applications, machinery processing, storage and voyage as  well as high requirements for export goods, VCI packages have got more  applications.</p>
<p>The principle of volatile corrosion inhibition is by using VCI,  volatile corrosion inhibitor which can be evaporated under normal  temperature so as to achieve saturation in the closed environment; VCI  molecules are absorbed onto the metal surface to form a transparent  protection film of several molecules thick after complicated physical  and chemical reactions. This transparent protection layer is water  proof, difficult to be dissolved and thus, can stop further corrosion.  Evaporated VCI molecules can reach anywhere in the package with best  anti-rust performance. VCI plastic material is manufactured by  polyolefin resin with VCI under processes.</p>
<p>Volatile corrosion inhibiting film testing should adopt US military  specification MII.PRF-22019D “Barrier Materials, Transparent, Flexible,  Sealable, Volatile Corrosion Inhibitor Treated” and other domestic and  international standards.</p>
<p><strong>1.VCI Thickness Testing</strong></p>
<p>Whether the thickness of VCI plastic film is even or not is the basic  for VCI film and its performances. Uneven thickness would affect the  tensile strength, permeation of different parts of the package; and  would affect the following processing. Thickness testing methods are  varied. For VCI plastic film thickness measurement, ISO 4593 and GB/T  6672-2001 are applicable.</p>
<p>Labthink PARAM CHY-C2 and CHY-CA Thickness Testers are both high  precision thickness testers for VCI plastic film thickness testing with  the resolution upto 0.1um. Labthink PARAM CHY-CA Thickness Tester,  besides its high precision, high efficiency and other characteristics  and functions to similar PARAM CHY-C2, is equipped with automatic  feeding system to satisfy the constant and effective testing  requirements of the clients with greater testing efficiency.</p>
<p><strong>2. VCI Plastic Film Impact Testing Instruments</strong></p>
<p>VCI (Volatile Corrosion Inhibition) plastic film impact property and  its control could avoid package breakage owing to the insufficient  toughness, so as to effectively get rid of product rustiness caused by  inferior impact or shock resistance of the VCI plastic packages during  circulation.</p>
<p>VCI plastic film impact testing is in compliance with ASTM D3420,  GB/T 8809-1958 and other international standards. Labthink PARAM FIT-01  Film Impact Tester is in strict compliance with these standards and with  more advanced functions. For example, Labthink PARAM FIT-01 Film Impact  Tester is of pneumatic specimen clamping and pneumatic pendulum  releasing, which is completely different from other products that are  manual clamping. Pneumatic clamping is rapid and effective with even  clamping force on the four sides of the film, and will not slide during  impact with inaccurate results. Besides, the precision of PARAM FIT-01  Film Impact Tester is up to 0.001J, whereas other impact testers are  mostly of mechanical type with low precision through reading the  graduation on the board.</p>
<p><strong>3. VCI Plastic Film Tear Resistance Testing</strong></p>
<p>The VCI (Volatile Corrosion Inhibition) packaging material may be  torn by exterior forces during storage and transportation. Sufficient  tear resistance can reduce the transmission of tear and avoid rusting  caused by leakage. The testing for tear performances of VCI packaging  material is of Elmendorf method; and Labthink PARAM SLY-S1 Tearing  Tester can be applied for this test. This tester is computer control,  display and horizontal adjustment that guarantees reliable and accurate  testing results; the unique ‘3-ring’analysis technology can help the  operators with more direct analysis and evaluation.</p>
<p><strong>4. VCI Seal Performance Testing</strong></p>
<p>VCI (Volatile Corrosion Inhibition) packages, owing to strict  requirements, its seal performance testing is quite important. Seal  performance is defined as the characteristic of avoiding alien substance  entering into or contents coming out of the package. Usual testing  methods are as follows:</p>
<p>4.1 Underwater Decompression Method:</p>
<p>Labthink PARAM MFY-01 Leak Tester is on underwater decompression  method according to GB/T 15171-94 Test Method for Leaks in Sealed  Flexible Packages. Put a certain amount of distilled water into the  vacuum chamber, and put the sealed vacuum container into the distilled  water completely. Then, set the testing pressure and testing time.  Usually, the vacuum degrees are 20, 30, 50 and 90 kPa, etc. Start  testing. When the leak tester has reached a certain vacuum degree, stop  vacuumizing and observe. The inner-out pressure difference of the  specimen will cause inferior quality specimen leak so as to test  leakage.</p>
<p>4.2 Pressured Testing Method</p>
<p>Labthink PARAM LSSD-01 Leak and Seal Strength Detector is of  pressured testing method. Imposing high pressure gas into the vacuum  container and test the pressure resistance, sealing degree and leak  indexes so as to test integration and seal performance of the vacuum  container.</p>
<p>Labthink, the excellent provider of testing instruments and testing  services, is devoted to provide most excellent and complete quality  control solutions for pharmaceutical, foodstuff, cosmetics, packaging,  printing, adhesive, automotive, petrochemistry, environment, biology,  new energy, construction, aviation and electronic industries worldwide.</p>
<p><strong>5. Barrier property testing</strong></p>
<p>Barrier property is defined as the barrier performance of packaging  material against liquid or gas permeable substances. The entry of oxygen  would greatly increase the possibility of oxidization of metal  contents, and the water vapor barrier property is of even more  importance.</p>
<p>For gas barrier property, Labthink introduces PERME VAC series Gas  Permeability Testers and Labthink PERME OX2/230 Oxygen Transmission Rate  Test System that comply with relevant ASTM, ISO or GB standards (such  as GB 1038 and GB 1037). For water vapor barrier property testing,  Labthink PERME TSY-T series Water Vapor Permeability Testers and  Labthink PERME W3/330 Water Vapor Transmission Rate Test System are  applicable.</p>
<p>Further details please feel free to contact Shirley via:<br />
TEL:  0086-531-85061080<br />
FAX: 0086-531-85062108<br />
EMAIL: trade2@labthink.cn<br />
SKYPE: shirley-labthink<br />
MSN: shirleywu_labthink@hotmail.com</p>
<p>More about <strong>Labthink(<a href="http://www.labthink.cn/en" target="_blank">http://www.labthink.cn/en</a>)</strong>:<br />
Labthink focusing on  the laboratory testing instruments R&amp;D and  production and laboratory IT  services, is dedicated to provide  professional quality control solutions for  customers in packaging,  food, pharmaceutical, medical, daily chemistry,  printing, adhesive,  automotive, petrochemistry, bioscience, construction, new  energy and  other industries.</p>
<p>Customers worldwide(parts):</p>
<p><a href="http://www.pendulum-impact.com/wp-content/uploads/2011/07/customers-logo.jpg"><img title="customers logo" src="http://www.pendulum-impact.com/wp-content/uploads/2011/07/customers-logo.jpg" alt="" width="746" height="715" /></a></p>
<p>Labthink, think for you only!</p>
]]></content:encoded>
			<wfw:commentRss>http://www.oxygen-transmission-rate.com/vci-volatile-corrosion-inhibition-package-quality-control-testing-solution.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
