Present Situation and Trend of Permeation Testing
Abstract: this article  introduces the present situation of permeation testing, and evaluates on  the hotspot as well as the prospect of the permeation testing.  Meanwhile, this article proposes some hints on how to select  instruments.
Key Words: permeation, precision, measurement, instrument selection, measuring range
Further details please feel free to contact Shirley via email: trade2@labthink.cn, (tel)0086-531-85811021 or visit our web: http://www.labthink.cn
With the strengthening of testing on food and pharmaceutical  packaging materials, the promotion of permeation testing has found  favorable opportunity. After several years of development, the number of  qualified permeation testing labs has increased from very few to  several hundred. Not only the number of instruments, but the detailed  testing items as well have been greatly broadened. At the same time,  there has been great focus on the relationship between permeation  testing of packaging materials and the shelf-life of the finished  products. Therefore, permeation testing has been greatly strengthened by  the manufacturers.
1. Present Situation
At present, the common instruments for permeation testing are of  differential pressure method for gas transmission rate testing and  weighing method for water vapor transmission rate testing. Besides,  equal pressure method for gas transmission rate testing and electrolytic  method for water vapor transmission rate testing have also found a  certain portion of applications.
2. Main Focuses
Firstly, market should evaluate the precision of the instruments  scientifically with a positive forward-looking view. The testing  precision of the instrument depends on the sensors. The precision and  stability of instruments on the same testing method work differently in  different time periods. Therefore, evaluation based on the testing  results of only one certain period is wrong. For example, with the great  progress made in pressure sensor and weighing sensor development during  the recent one or two decades, the precision of differential pressure  method and weighing method has achieved a historical height. However,  some reports neglected this point when citing documentations, and still  follow the evaluations in the past century on instruments of those two  methods, which do not comply with the actual situation. It’s sure that  with the continuous precision development, human interference on the  testing data has become more prominent. The experiences and skills of  the instrument operators would sometimes become the key factors  influencing the data stability and repeatability.
Secondly, the focus of instrument selection. Some users, when  selecting equal pressure instruments and sensor method instruments,  concern especially whether the sensor of the instrument is a absolute  value sensor or a relative value sensor. (Absolute value sensor includes  coulometric sensor and electrolytic water vapor sensor; relative value  sensor includes electrochemical sensor and infrared water vapor sensor.)  The author holds that such kind of instrument selection habit is  improper which would mislead their attention to some individual  components. On the contrary, the author thinks the complete performance  of the instrument should be the top concern. As to application, absolute  value sensor and relative value sensor are equally well. The author  disagrees that some promotional material says the life span of  electrochemical sensor is short. The author has long been experimenting  with electrochemical sensor oxygen permeation testers, and the testing  specimens are of varied permeation properties. According to actual use  in recent years, it’s out of question that the sensor can work stably  for more than 3 years (much longer than the description in some  reports), only if the users operate normally without operational errors.  Furthermore, the life span of absolute value sensor is relatively short  which can be further proved by the newly issued standard.
The author has the following suggestions on the permeation  instrument selection: first, the measuring range of the instrument  should be based on the permeability of the applied materials in  production. Usually, the lower limit of the permeation instruments can  meet the testing demands. Therefore, lower limit should be especially  concerned. Second, the decision to buy instrument of equal pressure  method or sensor method should be in accordance with the permeation  property of the material to be tested. It might be fatal for those  consuming sensors to test mediate and low barrier property materials.  Third, the data repeatability and stability of the instrument should be  taken into consideration. Usually, for testing institutes with uncertain  specimens, it’s necessary to choose instruments (usually, differential  pressure method and weighing method) with broad measuring range and  reasonable precision; for labs and enterprises with limited funds,  differential pressure method instruments and weighing method instruments  are also recommended since they are relatively universal.
Thirdly, how to apply measurement authentication for the permeation  testing instruments has always been the concerned by the quality  inspection labs. Permeation property testing instruments are different  from traditional mechanical and chemical testing instruments. For  permeation property testing instruments, standard substance is the best  method, that is, to inspect and calibrate with films or sheets (commonly  termed as reference film) of standard transmission rate. Some  information says only the N.I.S.T. can provide such kind of films, but  when the author contacts N.I.S.T. directly, there is no such kind of  film from N.I.S.T. Therefore, using film to calibrate permeation testing  instruments can only be regarded as the company method, not a means for  calibration. Take gas transmission rate testing instruments as an  example, pressure sensor, temperature sensor and humidity sensor can be  measured respectively. Whereas, the equal pressure instruments, no  matter absolute value sensor or relative value sensor is applied, can  only be measured by standard gas sensor. Thus, it should be noted that  the instruments that cannot be calibrated with standard gas will be in  trouble when inspecting and calibrating. Multi-spot calibration using  multi standard substances is a common measuring method, and is widely  used in mechanical, optics, chromatography and other technologies.  Multi-spot calibration is accurate and objective, with can greatly lower  the calibration failure rate.
3. Future Prospects
There has been great development of permeation testing instruments  in testing precision and testing method. And, with the further expansion  of permeation testing field, with the stricter testing requirements,  the future prospects of permeation testing are as follows:
First, special permeation testing instruments for different  industries will be developed. Now, one type of instrument is commonly  used in different industries. The introduction of special instrument  will change the present status of low professionalization. With the  extending of material permeation application, permeation testing is no  longer limited to packaging industry, and has found testing demands for  materials in automotive, textile, medical, construction, aviation and  electronics, etc. Moreover, permeation indexes have become the basis for  material selection. However, the material permeation property testing  is not identical to packaging material property testing caused by  different testing institutions, testing conditions, instrument measuring  ranges (e.g., the gas transmission rate of packaging materials and  textiles may differs millions of times) and formulas. Therefore, it is a  trend to develop special permeation testing instruments according to  different needs.
Second, more permeable substances will be expanded. Originally, the  permeation testing includes routine gases and water vapor permeation  testing. However, with the expansion of research areas, specialty gas  transmission rate testing has been the new frontier in permeation  testing. There have been great testing demands for organic gases,  explosive and dangerous gases and inert gases. Some of the specialty gas  testing has realized by way of improvement of the differential pressure  method instruments. As to gases with characteristics different from  routine gases, or dangerous gases, special testing instruments should be  developed. Therefore, the extension of testing substances is another  trend for permeation instruments.
4. Conclusions
Now, the indexes of permeation testers can satisfy requirements for  packaging industry completely, and have made great progress in  container package testing. At the same time, new technologies and new  methods have been applied increasingly, with only a few notable issues  in instrument selection and application. Development of special testing  instruments and expansion of testing substances are the two tendencies  in the permeation testing field. It’s foreseeable there will be  extensive and bright future for permeation testing.
Title:Present Situation and Trend of Permeation Testing
Link:http://service.labthink.cn/en/article-Permeation-info-110118143.html